Preview

Vestnik natsional'nogo issledovatel'skogo yadernogo universiteta "MIFI"

Advanced search

Application of the Multichannel Front-End Chip for SiPM-Based Gamma Detectors

https://doi.org/10.56304/S2304487X20040094

Abstract

   The prototype of a multichannel application specific integrated circuit (ASIC) designed at the National Research Nuclear University MEPhI as a front-end part of the gamma-detection systems utilizing “slow” scintillators such as NaI(Tl) or CsI(Tl) readout by Silicon Photomultipliers has been tested. The measurements have been carried on using a specially developed electronic test-board and a software package written in LABVIEW. The gamma-detector module includes a NaI(Tl) scintillator crystal and a matrix of SiPM PM6600 (KETEK) as a photosensor part. The system energy resolution (FWHM) has been measured to be (16.9 ± 0.9) % for 59.5 keV gamma rays. For comparison, the same measurements have been replicated using the analog part of the multichannel ASIC MAROC3 with observed energy resolution (27.7 ± 0.9) %.

About the Authors

A. C. Chergui
National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)
Russian Federation

115409

Moscow



O. V. Bychkova
National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)
Russian Federation

115409

Moscow



E. V. Popova
National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)
Russian Federation

115409

Moscow



A. A. Stifutkin
National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)
Russian Federation

115409

Moscow



References

1. Wernick M. N., Aarsvold J. N. Emission Tomography – The Fundamentals of PET and SPECT. Elsevier AcademicPress, 2004.

2. Popova E. V., Berdnikov V. V., Belyaev V. N. et al. SiPM MEPhI Megagrant Developments in Nuclear Medicine // Physics Procedia, 2015. V. 74. P. 36–43. doi: 10.1016/j.phpro.2015.09.189

3. https://www.weeroc.com/my-weeroc/download-center/citiroc-1a/1-citiroc-1a-one-sheet-description

4. https://www.weeroc.com/my-weeroc/download-center/petiroc-2a/2-petiroc-2a-one-sheet-description

5. https://www.weeroc.com/products/sipm-read-out/triroc-1a

6. https://www.weeroc.com/my-weeroc/download-center/maroc-3a/4-maroc-3a-one-sheet-description

7. https://www.weeroc.com/my-weeroc/download-center/catiroc-1/5-catiroc-1-one-sheet-description

8. https://www.petsyselectronics.com/web/website/docs/products/product1/Flyer_ASIC2_V15.pdf

9. https://ideas.no/products/va32hdr14-3/

10. https://ideas.no/products/ide3160-2/

11. https://ideas.no/products/ide3380/IDE3380SIPHRA

12. https://ideas.no/products/vata64hdr16-2/

13. Bocharov Y. I., Butuzov V. A., Simakov A. B. Application of a specific integrated circuit for readout and analog processing of signals from silicon multiplier arrays. Instruments and Experimental Techniques, 2017. Vol. 60, no. 6, pp. 800–810.

14. https://www.xfab.com/about-x-fab/

15. Morozov A., Solovov V., Alves F. et al. Iterative reconstruction of detector response of an Anger gamma camera // Physics in Medicine and Biology, 2015. V. 60. № 10. P. 4169–4184. doi: 10.1088/0031-9155/60/10/4169

16. www.ketek.net/

17. https://www.hirose.com/en/product/document?clcode=&productname=&series=DF17&documenttype=Catalog&lang=en&documentid=D49657_en

18. https://www.weeroc.com/my-weeroc/download-center/maroc-3a/4-maroc-3a-one-sheet-description/file

19. Scott D. W. Sturges’ rule // Wiley Interdisciplinary Reviews: Computational Statistics, 2009. V. 1. № 3. P. 303–306. doi: 10.1002/wics.35

20. Sturges H. A. The Choice of a Class Interval // Journal of the American Statistical Association, 1926. V. 21. № 153. P. 65–66. doi: 10.1080/01621459.1926.10502161

21. Freedman D., Diaconis P. On the histogram as a density estimator: L 2 theory // Zeitschrift Fur Wahrschein-lichkeitstheorie Und Verwandte Gebiete, 1981. V. 57. P. 453–476. doi: 10.1007/bf01025868

22. Birgé L., Rozenholc Y. How many bins should be put in a regular histogram // ESAIM: Probability and Statistics, 2006. V. 10. P. 24–45. doi: 10.1051/ps:2006001

23. GOST 26874–86. Spektrometryenergii ioniziruiuch’h izluchenii. Metody izmereniia osnovnyh parametrov. [State Standard 26874–86. Ionizing radiation power spectrometers. Methods of basic parameters measurement]. Moscow, 1987. 35 p.

24. https://www.originlab.com/doc/Origin-Help/Gaussian-Function-FitFunc


Review

For citations:


Chergui A.C., Bychkova O.V., Popova E.V., Stifutkin A.A. Application of the Multichannel Front-End Chip for SiPM-Based Gamma Detectors. Vestnik natsional'nogo issledovatel'skogo yadernogo universiteta "MIFI". 2020;9(4):357-367. (In Russ.) https://doi.org/10.56304/S2304487X20040094

Views: 111


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2304-487X (Print)